Vue de la page 111
CDA 7 Maintenance Manual
B-6 77 A7 48UU Rev03
STANDARDIZED DETAILED STATUS
DSB0
bit 0 Illegal command
bit 1 Illegal count
bit 2 Invalid data
bit 3 Illegal sequence
bit 4 Resume error
bit 5 RFU
bit 6 RFU
bit 7 Programmed release
DSB1
bit 0 Underrun/Overrun (for WSP the meaning is: device busy
longer than expected)
bit 1 Device not initialized
bit 2 Device Fault
bit 3 Device Off-line
bit 4 Device Interface error
bit 5 RFU
bit 6 Device Standby
bit 7 Device Time-out
DSB2
bit 0 No More Space Available
bit 1 Extra Byte (Last byte not valid)
bit 2 Partition Overflow
bit 3-5 RFU
bit 6 Manufacturer Defect List(Error occurred)
bit 7 Current Defect List "
DSB3: Partition Identifier, 0xFF if no block has been accessed during channel
program execution.
DSB4 to DSB7: Offset in data blocks from the beginning of the partition to the
block error or last block accessed during channel program.
DSB8
bit 0 Recovered Error With Retries
bit 1 Recovered Error With ECC Correction
bit 2 Automatic Reassign
bit 3 Recovered Device Fault
bit 4 Recovered Underrun/Overrun
bit 5 Reassign Required
bit 6 Header/Physical block fielderror
bit 7 RFU