Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HYT : 01949 862 012 F : 01949 862 003 E : cu
10Correct Use of the Optional Wok Pan Adaptor (hg6310 & hg6320 only)The wok pan adaptor is a special stand that is designed to be fitted over the t
11Care and MaintenenceAs the hob has a stainless steel or enamel surface, you should use a nonabrasive cleaner. Any abrasive cleaner (including Cif)
12Total rated gas input : 7.5kW (hg6300) 8.0kW (hg6310 & hg6320)Mains electrical voltage: 230 – 240Vac, 50HzTotal rated elec
13Mains Electricity ConnectionTHIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHE
14Gas Supply RequirementsIMPORTANT: THIS APPLIANCE SHOULD BE FITTED BY A GAS SAFE REGISTERED FITTER OR OTHER SUITABLY QUALIFIED PERSON.• Thisinstal
15Room Volume (m3) 56 to 106 to 1111 or moreAir Vent Required (cm2) 10050No permanent vent required if a door opens to the outsideNone requiredVentila
16Natural Gas to LPG ConversionThis hob can be converted from natural gas to propane operation at a nominal inlet pressure of 37mbar, or butane operat
17LPG to Natural Gas ConversionThis hob can be converted from propane operation at a nominal inlet pressure of 37mbar or butane operation at a nominal
18Fitting the HobUnpacking the hob:Take care not to lose or mishandle any parts.Fitting position of the hob:This appliance must be installed a minimum
19Fig. 11 15mmVentilation slot > 30mmwithstanding temperatures 65°C above ambient or greater (typically 80-90°C).• If there is no oven to be b
2ImportantThe manufacturer cannot be held responsible for injuries or losses caused by incorrect use or installation of this product.Please note that
202. Position the hob seal, as shown in the diagram below (Fig. 14), ensur-ing that the ends meet without overlapping. Do not use silicone type seal
21NOTES:
22NOTES:
23E & O E. All instructions, dimensions and illustrations are provided for guidance only. CDA reserve the right to change specifications without
Please contact our Customer Care Department for Service on the details belowCustomer Care Department • The Group Ltd. • Harby Road • Langar •
3safety (LVD) and Electromagnetic interference compatibility (EMC). Parts intended to come into contact with food conform to EEC/89/109.IMPORTANT INFO
4• This hob (Class 3) has been designed for use only as a cooking appliance. Any other use (e.g. heating rooms) should be considered incorrect and p
5Using Your HobFig. 1Gas burners:Gas flow to the burners is controlled by the control knobs (5, 6, 7 and 8 on the diagrams on pages 6 & 7). There
6ghg6300Fig. 2hg6310Fig. 3333321445 6 7 85 6 7 8
7Key to Figs 2, 3 & 4Gas burners:1. Triple burner 3.5kW2. Rapid burner 3.0kW3. Semi-Rapid burner 1.75kW4. Auxiliary burner 1
8Igniting the BurnersThe hob is fitted with a flame failure device. Flame failure devices operate by shutting o the supply of gas to the burner in the
9Fig. 6Ecient Use of Your HobThe hob is equipped with burners of dierent sizes, designed to accommodate most shapes and sizes of pan. For best resu
Commentaires sur ces manuels