Vue de la page 8
9
F
C
Flame failure
probe “T
Ignitor S
Correct Positioning of the Auxiliary, Semi-rapid and Rapid Burners
It is very important to check that the burner ame spreader F and the cap C have been correctly
positioned (see gs. 6 and 7). They shall be level and must not rotate. Failure to do so can cause serious
problems.
The pan supports shall be correctly positioned as indica-
ted in g. 8. The pan supports shall be level and must not
rotate.
Fig.7
Fig. 8Fig. 6