Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HYT : 01949 862 012 F : 01949 862 003 E : se
10Remove the old bulb from the holder.Fit the new bulb, taking care not to touch the glass of the bulb.Take care to ensure any tools used do not damag
11InstallationPositioning the vent outlet:The motor unit can be turned to position the outlet to any of the four sides. 1. Open the decorative cover
12InstallationInstalling the extractor:The extractor can be mounted directly into the ceiling, where space between the ceiling and joists permits, or
134. Drill the dierent holes required for the mounting, as below, using a drill bit suitable for the ceiling material:• The 150mm diameter vent ou
14ceiling, use a sleeve to prevent damage to the plasterboard when the four 10mm nuts and bolts are being tightened.When the ceiling is concrete, use
15Installation Into a False Ceiling: (Two persons required)1. Open the decorative cover panel and remove the two grease filters.2. Remove the light p
16fig. 153. The extractor is intended to be secured to the ceiling using the four adjustable spring-loaded clips; these are shown in the image below:4
17the adjustment screw to secure the extractor firmly in positionNote:When fixing to an 18mm MDF false ceiling, four 2mm spacers have been provided to m
18Ducting: The extractor can be used as a recirculation device or as a extraction device, depending on your installation.The hood is more eective whe
19Re-Circulation:An internal air vent is required, as shown below. This ensures that the air is placed back in the kitchen after it has been filtered
2ImportantThe CDA Group Ltd cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. Please note th
20Adjusting the Position of the Decorative Cover Panel: The decorative panel can be finely adjusted by moving the positions of the cover hinges, as sho
21Typical Installation Examples:
22Changing the LightIMPORTANT: DO NOT PERFORM MAINTENANCE OR ATTEMPT TO CLEAN THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY.DO NOT
23Synchronising the remote control with the extractorWhen the extractor is o, press and hold button “B”, and then switch the extractor on.After five s
24Mains Electricity ConnectionTHIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHE
25• The wire which is coloured brown must be connected to the terminal marked L (Live), or coloured red.Note: Use a 3A FuseAssembly and electrical c
26Electrical InformationMains electrical voltage: 230 – 240Vac.Total rated power consumption evx100 / evx140: 410W.TroubleshootingPlease note:Your ext
27Attribute Symbol Value UnitsModel Identification evx100/140Annual Energy Consumption AECHood201.7 kWhTime increase factor f 1.0Fluid Dynamic Efficie
Please contact our Customer Care Department for Service on the details below.Customer Care Department • The Group Ltd. • Harby Road • Langar
3IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2002/96/EC.At the end of its working life, the product must
4Please note:• Under no circumstances should the extractor be connected to any gas ventilation system, flue system or hot air ducting system.• Do
5Using Your ExtractorFor best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately
6remote control. Whilst the intensive function is active “HI” appears on the centre of the display and the bottom right hand dot flashes once a second
7- To activate the clean air function, touch key “E” when the appliance is either on or o. When the clean air function is running, “24” will show on
8To reset the filter alarm, press button “E” for approximately 3 seconds when the extractor is switched o.To remove the grease filters follow the steps
9should remove and replace the charcoal filters.To attach a new charcoal filter, first open the cover panels and remove the grease filters as described ab