HVG MIXED-REFRIGERATION MODES 30º-270ºC
fig 21
REGENERATION MODE:
- Initial phase: Both burners simultaneously chimney open.
-Temperature maintenance: Burners cycle alternatively. 1
st
Convection chimney open and 2
nd
Steam- chimney closed. (Steam cycles in turn with the RE1 energy regulator 15 sec. ON and 15sec.
OFF)
MIXED MODE:
-Initial phase: Convection burner chimney open.
-Temperature maintenance: Burners cycle . 1
st
Convection chimney open and 2
nd
Steam- chimney
closed. (Steam cycles in turn with the RE1 energy regulator 15 sec. ON and 15sec. OFF)