CDA hg6120 Spécifications Page 13

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 12
13
Room Volume (m
3
)
5
6 to 10
6 to 11
11 or more
Air Vent Required (cm
2
)
100
50
No permanent vent required if a door opens to the outside
None required
Ventilation
All rooms require a window or equivalent (e.g. a door) which can be
opened. Some rooms require a permanent vent in addition to a win-
dow (see below).
This unit must not be used in a room which is less than 5m
3
. The
following table details the requirements based on the kitchen volume
(L x W x H) in m
3
.
The above requirements also allow use of a gas oven and grill but if
there are any other fuel burning appliances in the same room, consult
the relevant British Standard (BS5440) or GAS SAFE document.
Vue de la page 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 19 20

Commentaires sur ces manuels

Pas de commentaire