13
- Repairs on electrical parts
Before calling the Technical Assistance Service check that:
-
The plug has not come out of the socket.
-
The main switch in the home is on.
If necessary, have the appliance serviced by qualified personnel.
Remove the plug from socket before disassembling any part.
- Replacement of feed cable
The feed cable must be in HO5 RR-F, with a cross sectional area of 3x1 mm².
It can be replaced as follows:
- open the terminal board;
-
connect the wires to their terminals: N – L – Earth;
-
secure the wire with the cable clamp;
- close the terminal board with screws;
Fig. 5
N.B.:
After installation the lead must be accessible.
- Adapting hob burners to other types of gases
These hob models are fitted with burners that require no air regulation. For this
reason, to adapt the appliance to work with a gas different to what it has been set
for, simply substitute the nozzles and adjust the minimum.